International Comfort Products NDN6050FBA1 Defrost Sensor Board
The defrost sensor board instructs the system to activate an important defrosting cycle which may be needed in order to remove frost build-up that may accumulate. The defrost board is influenced by a temperature sensor located in the outdoor unit to verify when to initiate the defrosting cycle.
Elements of a bad AC defrost sensor board
- The main control board may throw an error number referring to a failing defrost control board
- AC and heating system could not work at all because of frost blocking the fins on the outside unit
- The defrost sequence will not initiate despite the fact that there is quite a bit frost built up